VTS30
Related Products
Technical Drawing & Dimensions

| Art No. | d3 | L | L1 | h | d1 | d2 | A/F |
|---|---|---|---|---|---|---|---|
| VTS30-M5×20 | M5 | 20 | 6 | 7.63 | 10.85 | 11.5 | 8 |
| VTS30-M5×25 | M5 | 25 | 6 | 7.63 | 10.85 | 11.5 | 8 |
| VTS30-M5×30 | M5 | 30 | 6 | 7.63 | 10.85 | 11.5 | 8 |
| VTS30-M5×35 | M5 | 35 | 6 | 7.63 | 10.85 | 11.5 | 8 |
| VTS30-M5×40 | M5 | 40 | 6 | 7.63 | 10.85 | 11.5 | 8 |
| VTS30-M5×45 | M5 | 45 | 6 | 7.63 | 10.85 | 11.5 | 8 |
| VTS30-M5×50 | M5 | 50 | 6 | 7.63 | 10.85 | 11.5 | 8 |
| VTS30-M6×20 | M6 | 20 | 8 | 8.14 | 12.85 | 13.5 | 10 |
| VTS30-M6×25 | M6 | 25 | 8 | 8.14 | 12.85 | 13.5 | 10 |
| VTS30-M6×30 | M6 | 30 | 8 | 8.14 | 12.85 | 13.5 | 10 |
| VTS30-M6×35 | M6 | 35 | 8 | 8.14 | 12.85 | 13.5 | 10 |
| VTS30-M6×40 | M6 | 40 | 8 | 8.14 | 12.85 | 13.5 | 10 |
| VTS30-M6×50 | M6 | 50 | 8 | 8.14 | 12.85 | 13.5 | 10 |
| VTS30-M8×20 | M8 | 20 | 10 | 9.12 | 15.85 | 16.4 | 13 |
| VTS30-M8×25 | M8 | 25 | 10 | 9.12 | 15.85 | 16.4 | 13 |
| VTS30-M8×30 | M8 | 30 | 10 | 9.12 | 15.85 | 16.4 | 13 |
| VTS30-M8×40 | M8 | 40 | 10 | 9.12 | 15.85 | 16.4 | 13 |
| VTS30-M8×50 | M8 | 50 | 10 | 9.12 | 15.85 | 16.4 | 13 |
| VTS30-M8×60 | M8 | 60 | 10 | 9.12 | 15.85 | 16.4 | 13 |
| VTS30-M8×70 | M8 | 70 | 10 | 9.12 | 15.85 | 16.4 | 13 |
| VTS30-M8×75 | M8 | 75 | 10 | 9.12 | 15.85 | 16.4 | 13 |
| VTS30-M10×20 | M10 | 20 | 12 | 9.5 | 18.85 | 19.2 | 16 |
| VTS30-M10×25 | M10 | 25 | 12 | 9.5 | 18.85 | 19.2 | 16 |
| VTS30-M10×30 | M10 | 30 | 12 | 9.5 | 18.85 | 19.2 | 16 |
| VTS30-M10×40 | M10 | 40 | 12 | 9.5 | 18.85 | 19.2 | 16 |
| VTS30-M10×50 | M10 | 50 | 12 | 9.5 | 18.85 | 19.2 | 16 |
| VTS30-M10×60 | M10 | 60 | 12 | 9.5 | 18.85 | 19.2 | 16 |
| VTS30-M10×70 | M10 | 70 | 12 | 9.5 | 18.85 | 19.2 | 16 |
Dimensions in mm. L1 indicates the threaded end length.
Installation requirements: Captive retention requires a compatible cover-hole design or a suitable retaining component. A plain clearance hole alone will not retain the screw. Confirm the cover thickness, reduced-shank clearance and thread engagement for the intended assembly.
Technical Data
- Screw Body
- AISI 316L stainless steel / EN 1.4404
- Certification
- 3-A certifiedIP69K
- Surface Finish
- Mirror-polished · Ra < 0.4 µmNatural · Ra < 0.8 µm
- HNBR Sealing Ring
- Blue, 85 ±5 Shore A, −25 °C to +150 °C
- EPDM Sealing Ring
- Blue, 85 ±5 Shore A, −40 °C to +120 °C
- Steel Grade and Property Class
- M5–M10: A4-80
FDA compliance applies to the sealing-ring material.
Seal selection depends on the cleaning media, operating temperature and application conditions.
Hygienic Design Bolts Features
This hygienic captive screw is made from high-quality, cold-drawn 316L stainless steel, with rolled threads and a mirror-polished finish with a surface roughness of Ra < 0.4 μm. It offers excellent corrosion resistance and high mechanical strength. Its smooth geometry and rounded, burr-free edges help minimize dirt and bacterial buildup and reduce liquid retention, making it easier to clean and sterilize in place (CIP and SIP).
Seal Fit Optimized Through Finite Element Simulation
We combined simulations based on the finite element method (FEM) with practical engineering experience to refine the sealing ring’s thickness, diameter and dimensional tolerances. As the fastener is tightened, the ring compresses and conforms to the stainless steel groove, closing the exposed gap at the mounting interface. This helps keep cleaning solution from collecting in the joint and reduces the risk of microbial contamination.
All food-grade HNBR and EPDM raw rubber used in our seals comes from ARLANXEO. These seals are manufactured exclusively in a production area dedicated to food-grade rubber components to prevent cross-contamination with industrial-grade rubber. We control every stage, from receipt of raw materials through seal manufacture.
Single-Pass Turning of Hex Flats
VAYTRON developed a turning process that forms the wrench flats on its hex-head fasteners in a single pass. The process keeps the hex profile precisely centered on the fastener axis while controlling burrs and machining marks along the edges of the flats. The wrench seats securely against the flats during tightening, distributing the load more evenly across the contact faces and reducing the risk of scratching the bolt head.
Captive Fastening for Removable Covers
VTS30 is intended for covers and access panels that are removed for cleaning, inspection or maintenance. Its reduced shank allows the fastener to be retained by a suitable feature in the cover after the end thread has disengaged from the housing.
The captive function helps keep the fastener with the cover during servicing. The blue sealing ring serves a separate function: sealing the head-to-surface interface when the screw is tightened.
Metal-to-Metal and Seal-Free Options
Through our discussions with pharmaceutical equipment manufacturers, we have found that elastomer seals are unsuitable for some high-temperature sterilization and cleaning processes. However, these applications may still require sealing at the fastening point.
Contact us to discuss whether a metal-to-metal seal or seal-free configuration is suitable for the selected model and joint design.
Hygienic screw with a metal-to-metal seal: This option requires a suitable joint design and a sealing contact surface precisely finished to Ra < 0.8 µm.
Hygienic screw without a seal: Consider this option where sealing is unnecessary.
Applications
Typical applications: removable machine covers, maintenance access panels and hygienic equipment housings in food, beverage and pharmaceutical machinery, subject to the assembly design.
Hygienic stainless steel bolts are widely used in:
· Food processing equipment
· Dairy production systems
· Beverage filling and packaging lines
· Pharmaceutical manufacturing machinery
· Biotech and cleanroom equipment
· Industrial washing and hygiene-critical environments
FAQ
What is the difference between HNBR and EPDM seals?
HNBR: High mechanical strength and good resistance to oil, heat, wear, ozone, and ageing. Well suited to demanding sealing applications involving oils and lubricants.
EPDM: Excellent resistance to weathering, ozone, hot water, and steam, with good flexibility at low temperatures. Generally unsuitable for petroleum-based oils and fuels.
Based on our market observations, HNBR seals are common in food-processing equipment and EPDM seals in pharmaceutical equipment. For other applications, contact us to confirm the suitable material.
The selected compound and complete cleaning cycle must suit the application. Temperature limits alone do not establish compatibility with every steam or sterilization process.
What FDA requirements do VAYTRON’s rubber seals meet?
The HNBR and EPDM rubber sealing materials used in VAYTRON hygienic bolts comply with the applicable requirements of U.S. FDA 21 CFR § 177.2600 for rubber articles intended for repeated contact with food. The regulation sets requirements for rubber formulation and specifies limits on total extractives from finished rubber articles intended for repeated contact with aqueous or fatty foods.
Will the screw stay in any cover hole?
No. A matching retaining feature in the cover or a suitable retaining component is required. An ordinary clearance hole alone does not provide captive retention.
Is the reduced shank an anti-loosening feature?
Its purpose is to allow captive mounting during disassembly. Requirements for vibration resistance and maintaining clamp load must be assessed separately.
What should I provide when requesting a quotation?
Specify the thread size, length L, finish and seal material. Include the cover thickness and a drawing of the mating assembly when you need help checking captive retention.