Latch Pin & Housing
- Stainless steel: AISI 304 / 1.4301 or AISI 316L / 1.4404
- Surface roughness: Ra < 0.8 µm
- FDA compliant

| D (mm) | 29.9 | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| H (mm) | 18 | |||||||||||||
| T (mm) | 4 | |||||||||||||
| Panel Cut-out Diameter: | Please refer to the Install Guide. | |||||||||||||
| BH (mm) |
17F | 16F | 14F | 12F | 10F | 8F | 6F | 4F | 2F | 0 | ||||
| 2 | 4 | 6 | 8 | 10 | 12 | 14 | 16 | 17 | 18 | 20 | 22 | 24 | 26 | |
| 28 | 30 | 32 | 34 | 35 | 36 | 38 | 40 | 45 | ||||||
The VTCL creates a secure closure with a maximum 90° rotation. As the actuator turns, the latch arm moves into the closed position behind the frame. Its rounded operating surface and sealing arrangement are designed to reduce exposed recesses and support cleaning around enclosure doors, machine panels and access covers.
Stainless Steel Components: The latch pin and housing are available in AISI 304 / 1.4301 or AISI 316L / 1.4404 stainless steel. The latch tongue, counter nut and M6 flange bolt are AISI 304 / 1.4301 stainless steel.
FDA-Compliant Blue Seals: The outer housing seal is blue HNBR. The pin O-ring and inner housing seal are blue food-grade VMQ silicone. The seals support the sealing function around the latch assembly and make the sealing area easier to identify during inspection. The final enclosure protection level depends on the panel installation and enclosure design.
Smooth, Drainable Surface: The latch pin and housing have a surface roughness of Ra < 0.8 µm. Rounded external geometry helps water and cleaning media drain away while reducing areas where residue can remain.
90° Locking Action: A maximum quarter-turn moves the latch arm behind the frame, providing repeatable closure for control cabinets, machine doors and access panels.
BH Selection Options: The VTCL range includes F-series configurations and the BH options listed above, up to 45 mm. The correct part number should be selected according to the panel thickness, frame position and required latch engagement shown on the equipment drawing.